smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-60-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HDS721010DLE630
Serial Number:    MSE5215V085L7L
LU WWN Device Id: 5 000cca 37cc3b7f2
Firmware Version: MS2OA5Q0
User Capacity:    1.000.204.886.016 bytes [1,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Sat Mar 29 12:43:51 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                ( 7313) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 122) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       1
  2 Throughput_Performance  0x0005   095   095   054    Pre-fail  Offline      -       528
  3 Spin_Up_Time            0x0007   125   125   024    Pre-fail  Always       -       184 (Average 182)
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       19
  5 Reallocated_Sector_Ct   0x0033   092   092   005    Pre-fail  Always       -       251
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   118   118   020    Pre-fail  Offline      -       33
  9 Power_On_Hours          0x0012   098   098   000    Old_age   Always       -       15842
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       19
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       55
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       55
194 Temperature_Celsius     0x0002   193   193   000    Old_age   Always       -       31 (Min/Max 23/45)
196 Reallocated_Event_Count 0x0032   095   095   000    Old_age   Always       -       260
197 Current_Pending_Sector  0x0022   075   075   000    Old_age   Always       -       640
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 2028 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2028 occurred at disk power-on lifetime: 15832 hours (659 days + 16 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 c0 4a f7 07  Error: UNC at LBA = 0x07f74ac0 = 133647040

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 c0 4a f7 40 00      00:32:07.142  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      00:32:07.142  SET FEATURES [Reserved for Serial ATA]
  27 00 00 00 00 00 e0 00      00:32:07.142  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      00:32:07.141  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:32:07.141  SET FEATURES [Set transfer mode]

Error 2027 occurred at disk power-on lifetime: 15832 hours (659 days + 16 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 c0 4a f7 07  Error: UNC at LBA = 0x07f74ac0 = 133647040

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 c0 4a f7 40 00      00:32:03.938  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      00:32:03.938  SET FEATURES [Reserved for Serial ATA]
  27 00 00 00 00 00 e0 00      00:32:03.938  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      00:32:03.937  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:32:03.937  SET FEATURES [Set transfer mode]

Error 2026 occurred at disk power-on lifetime: 15832 hours (659 days + 16 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 c0 4a f7 07  Error: UNC at LBA = 0x07f74ac0 = 133647040

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 c0 4a f7 40 00      00:32:00.734  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      00:32:00.734  SET FEATURES [Reserved for Serial ATA]
  27 00 00 00 00 00 e0 00      00:32:00.734  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      00:32:00.733  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:32:00.733  SET FEATURES [Set transfer mode]

Error 2025 occurred at disk power-on lifetime: 15832 hours (659 days + 16 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 c0 4a f7 07  Error: UNC at LBA = 0x07f74ac0 = 133647040

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 00 c0 4a f7 40 00      00:31:57.531  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      00:31:57.531  SET FEATURES [Reserved for Serial ATA]
  27 00 00 00 00 00 e0 00      00:31:57.531  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      00:31:57.530  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:31:57.530  SET FEATURES [Set transfer mode]

Error 2024 occurred at disk power-on lifetime: 15832 hours (659 days + 16 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 c0 4a f7 07  Error: UNC at LBA = 0x07f74ac0 = 133647040

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 08 30 7d 17 40 00      00:31:54.319  READ FPDMA QUEUED
  60 08 00 c0 4a f7 40 00      00:31:54.319  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      00:31:54.318  SET FEATURES [Reserved for Serial ATA]
  27 00 00 00 00 00 e0 00      00:31:54.318  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 00      00:31:54.317  IDENTIFY DEVICE

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      5023         -
# 2  Short offline       Completed without error       00%      4967         -
# 3  Extended offline    Completed without error       00%       340         -
# 4  Short offline       Completed without error       00%       289         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.